LSK 2130-4K: Pure. Purer. sterilAir.

The UVC air disinfection
system with impressively confirmed effectiveness

The sterilAir LSK 2130-4K air disinfection system is an effective and elegant air purifier that reliably eliminates viruses, bacteria and spores. The device is easy to handle and maintain. The often copied original sterilAir was already successfully in use before the corona virus pandemic.

Effect against SARS CoV-2

The latest study looks at the effect of LSK 2130-4K on SARS-CoV-2, tested by microsearch UK, one of England's most renowned laboratories. Tested using Phi6 bacteriophages, which behave identically to SARS-CoV-2 and are considered an official surrogate, the analysis was carried out realistically in an airtight room of 28.3 m³.

 

Effective against airborne viruses
and pathogenic germs

Use in laboratories, offices, recreation rooms,
surgeries and clinics

For highly frequented rooms

 

Especially low noise

Shapely design

Low power consumption
with maximum safety

Impressive result

99,999999995% virus reduction after only 60 minutes! After this short time, only 47 infectious Phi6 bacteriophages (SARS CoV-2 surrogates) were detected per ml of air. At the beginning of the test the figure was 8‘800‘000‘000 /ml. This confirms that the use of the LSK 2130-4K air disinfection unit from sterilAir effectively and efficiently ensures air hygiene conditions without hesitation.

Markedly declining
microbial load

The result shows impressively that the virus load is reduced to a minimum within a very short time. By using the LSK 2130-4K air recirculation unit, the outstanding sterilisation performance ensures a safe air environment quickly and continuously.

This guarantees the safety of employees, the safety of customers and hygiene standards.

Technical data

PRODUCT DESIGNATION LSK 2130-4K
Power consumption 82 W, 0.36 A
Supply voltage 230 VAC ±4%, 50..60 Hz
Total output, UVC254nm 20 W
Tube types 2x UVC 2030-4K
Tube change interval 12‘000 Std. (75% ±5% residual performance)
Air circulation 140 m3/ hour
Noise emission 39 dBA
Material Stainless steel (WN 1.4301), lacquered sheet steel, PVC
Qualification CE, EMV
IP protection IP 50

Application examples

 

Do you have questions?

The power of UVC hygiene, for example, for your office or practice. Contact our specialist advisers for UVC disinfection systems today:

 

sterilAir AG
Oberfeldstrasse 6
CH-8570 Weinfelden

info@sterilair.com


Phone: +41 (0)71 / 626 98-00
Fax: +41 (0)71 / 626 98-10

sterilAir EU-Lager
August-Borsig-Strasse 13
D-78467 Konstanz

info@sterilair.de


Phone: +49 (0)7531 / 584 60-0
Fax: +49 (0)7531 / 584 60-99

sterilAir UK Ltd
Murley Moss Business Village
Kendal, LA9 7RL

info@sterilair.co.uk


Phone: +44 (0)1524 805908